# FALL OF ROOF OR BACK
> MSHA accident `220001430124` · 05/14/2000 · Consol Of Kentucky Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** CONSOL Energy Inc
- **Operator:** Consol Of Kentucky Inc
- **Mine:** [1517894](https://api.ai-analytics.org/mine/1517894)
## Narrative

AN UNINTENTIONAL ROOF FALL OCCURRED AT 15 BRK ON THE #8 BELT, 1 BRK INBY SPAD #2063. SIZE OF FALL WAS APPROX 35'W X 37'L X 6'H. NO INJURIES, VENTILATION WAS NOT INTERUPTED, BELT WAS CAUGHT, TH E AREA HAD BEEN SUPPORTED WITH 4' FULLY GROUTED RESIN BOLTS WITH ADDITIONAL SUPPORT CONSISTING OF 6' FULLY GROUTED RESIN BOLTS. FALL HAS BEEN CLEANED UP.

---