A NEW ROOF FALL OCCURRED IN THE 1 BUFF 1 NEST SECTION INT HE 5 ENTRY. LOCATION OF FALL WAS IN THE LOX INTERSECTION FALL IS APPROX. 21' LONG X 21' WIDE BY 4-6 HIGH AREA BOLTED WITH 4' RESIN BOL TS FULLY BROWNED. FALL WAS CLEANED UP AFTER GETTING MINER OUT FROM UNDER THE ROCK. CAUSE OF FALL WAS BEAN FAILURE CREATED BY BOLTS AND ADVISE ROOF CONDITION.