ROOF FALL IN THE #1 UNIT OF THE NEW EAGLE MINE #4 ENTRY AT 11 & 40. THE FALL IS IN AN INTERSECTION AND PART OF A CROSSCUT, IS 40 FT WIDE, 10 FT HIGH, 22 FT LONG. THERE IS A SMALL CLAY VEIN RUN NING ALONG RIGHT, IN BY SIDE AT AN ANGLE. AREA WAS SUPOORTED WITH 7 FT POINT ANCHOR BOLTS. NO SUPPLEMEMTAL BOLTS INSTALLED.