A ROOF FALL OCCURRED IN THE #5 ENTRY OF THE 1 WEST 1 BUTT SECTION ONE X-CUT INBY STA #19135. NO PERSONS WERE INJURED, VENTILATION WAS NOT INTERRUPTED. FALL WAS 60'LONG, 18'WIDE, 6'HIGH. AREA W AS BOLTED WITH 4' RESIN ROUTS. HIGH VOLTAGE CABLE WAS DAMAGED BY FALL. NEW CABLE WAS REROUTED. INTAKE ESCAPEWAY WAS REROUTED. FALL WILL NOT BE CLEANED UP. ALL WAS TIMBERED OFF.