← MSHA accidents

FALL OF ROOF OR BACK

220001960065 · 07/10/2000 · Canterbury Coal Company

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
Mine experience
— years

Operator

Controller (parent)
Robert E Murray
Operator
Canterbury Coal Company
Mine
3605708

Narrative

A ROOF FALL OCCURRED IN THE #5 ENTRY OF THE 1 WEST 1 BUTT SECTION ONE X-CUT INBY STA #19135. NO PERSONS WERE INJURED, VENTILATION WAS NOT INTERRUPTED. FALL WAS 60'LONG, 18'WIDE, 6'HIGH. AREA W AS BOLTED WITH 4' RESIN ROUTS. HIGH VOLTAGE CABLE WAS DAMAGED BY FALL. NEW CABLE WAS REROUTED. INTAKE ESCAPEWAY WAS REROUTED. FALL WILL NOT BE CLEANED UP. ALL WAS TIMBERED OFF.

Source

Authoritative
MSHA Open Government Data
Machine