ROOF FALL IN THE NEW EAGLE #1 UNIT 3 EAST 16 X CUT 7 ENTRY INTERSECTION. THE FALL IS 17 FT LONG 17 FT WIDE AND 8 FT HIGH DOMED. THE INTERSECTION HAD A CLAY VEIN RUNNING WIDTHWISE THROUGHOUT. T HE AREA WAS MINED 7-9-00 WITH A CONTINUOUS MINERAND SUPPORTED WITH 7 FT POINT ANCHOR ROOF BOLTS WITH HEADER BOARDS.