# FALL OF ROOF OR BACK
> MSHA accident `220001990089` · 07/05/2000 · Coastal Coal-West Virginia Llc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** El Paso Energy Corp
- **Operator:** Coastal Coal-West Virginia Llc
- **Mine:** [4608285](https://api.ai-analytics.org/mine/4608285)
## Narrative

A ROOF FALL OCCURRED ON 4 EAST #7 SECTION (MMV-003), #30 BLOCK, #5 HDG. THE FALL OCCURRED IN A 4-WAY INTERSECTION; FALL WAS APPROX. 18' W X 18' L X 6' H OR HIGHER. IT WAS BOLTED TO PLAN USIN G 6' X 3/4"" FULLY GROUTED RESIN BOLTS. FALL WAS DANGERED OFF AND WILL NOT BE CLEANED UP.

---