AN UNPLANNED ROOF FALL OCCURRED IN THE #2 ENTRY OF THE ABANDONED 3 LEFT SECTION. FALL STARTED JUST OUTBY SURVEY STATION #3338 & CONTINUED OUT BY FOR APPROXIMATELY 125' IN LENGHT, 19' WIDE, 10-12' HIGH. DID NOT AFFECT ANY EQUIPMENT OR VENTILATION. AREA TIMBERED AND DANGERED OFF. AREA BOLTED WITH 4' FULLY GROUTED BOLTS.