# FALL OF ROOF OR BACK
> MSHA accident `220002340140` · 08/07/2000 · Wayne Processing Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Rex  Fought
- **Operator:** Wayne Processing Inc
- **Mine:** [4608622](https://api.ai-analytics.org/mine/4608622)
## Narrative

AN UNINTENTIONAL ROOF FALL OCCURRED ON THE C-2 SUB-MAINS (002-0), NO. 6 ENTRY, 3 BLOCKS OUTBY POWER CENTER (TRACK ENTRY) AS SURVEY STATION NO. 4979. THE FALL IS APPROX. 60' LONG X 17' WIDE X 1 4' HIGH. THE FALL CONTAINED 5' RESING TENSION BOLTS. THE AREA WAS DEVELOPED 7-12-00. THE FALL WILL BE CLEANED UP & THE AREA SUPPORTED TO PLAN.

---