# FALL OF ROOF OR BACK
> MSHA accident `220002340197` · 08/13/2000 · Canyon Fuel Company LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Arch Resources Inc
- **Operator:** Canyon Fuel Company LLC
- **Mine:** [4201566](https://api.ai-analytics.org/mine/4201566)
## Narrative

A ROOF FALL WAS FOUND BY A PUMPMAN IN THE 8 LEFT RETURN. HE ROOF FALL MEASURED 10 FT BY 10 FT BY 3 FT HIGH. THE ROOF MATERIAL HAD FALLEN OUT BETWEEN THE BOLTS. THIS FALL BLOCKED TO SECONDARY E SCAPEWAY. ROOF JACKS WERE SET AND ESCAPEWAY MADEPASSIBLE BEFORE EMPLOYEES WERE ALLOWED TO ENTER THE SECTION.

---