A FALL OCCURRED APPROX. 250' OUTBY THE FACE OF #2 ENTRY ON THE 1ST LEFT SECTION OFF OF GRASSY CREEK MAINS; THE FALL IS APPROX. 40'L, 22'W AND IN EXCESS OF 12'H. THE AREA WAS BOLTED WITH 5' TE NSION REBAR BOLTS; THE AREA HAD BEGUN TO WORK AND DAY SHIFT HAD STARTED SPOTTING 8' BOLTS IN THE INTERSECTION. NO INJURIES OCCURRED; NO EQUIPMENT WAS INVOLVED. FALL OCCURRED IN INTERSECTION.