← MSHA accidents

HOISTING

220002490039 · 08/28/2000 · The Doe Run Company

Details

Degree of injury
ACCIDENT ONLY
Classification
HOISTING
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
Renco Group
Operator
The Doe Run Company
Mine
2300409

Narrative

HOIST LOST POWER AT 3:10 PM AND ELECTRICIANS WERE CALLED TO REPAIR IT. MSHA WAS CALLED AT 3:23PM AND TOLD THAT #31 HOIST AT FLETCHER WAS OUT OF SERVICE. THE ELECTRICIANS FOUND ALL AUXILLARY C ONTACT THAT WAS BAD ON THE MAIN LOWER CONTACTS AND CAHNGED IT OUT. HOIST WAS RETURNED TO SERVICE AT 5:29 PM SAME DAY AND MSHA WAS CALLED AND TOLD HOIST WAS BACK IN SERVICE.

Source

Authoritative
MSHA Open Government Data
Machine