A FALL OF ROOF OCCURRED IN THE WEST MAIN ENTRIES INBETWEEN X-CUT 38 AND 39 IN THE #5 ENTRY APPROX 7600 FT OUTBY #1 UNIT. THE FALL WAS APPROX 50'LX 18'W X 6 1/2'H. THE AREA WAS SUPPORTED WITH 6' FULLY GROUTED BOLTS AND HEINTZMAN SQUARE SETS. THE AREA WAS MINED APPROX 9-15-98.