← MSHA accidents

ELECTRICAL

220002620115 · 09/07/2000 · Newtown Energy Inc

Details

Degree of injury
DAYS AWAY FROM WORK ONLY
Classification
ELECTRICAL
Accident type
Flash burns (electric)
Occupation
Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator
Activity
Electrical maintenance
Injury source
ELECTRICAL APPARATUS,NEC
Nature of injury
ELECT.ARC BURN-NOT CONTAC
Body part
MULTIPLE PARTS (MORE THAN ONE MAJOR)
Days lost
60
Mine experience
0.46 years

Operator

Controller (parent)
James O Bunn; Franklin D Robertson
Operator
Newtown Energy Inc
Mine
4608759

Narrative

INJURED PERSON WAS RESETTING CIRCUIT BREAKER WHEN THE BREAKER MALFUNCITONED AND BLEW UP RESULTING IN BURN INJURIES.

Source

Authoritative
MSHA Open Government Data
Machine