← MSHA accidents

FALL OF ROOF OR BACK

220002650046 · 09/14/2000 · Wayne Processing Inc

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
Rex Fought
Operator
Wayne Processing Inc
Mine
4608622

Narrative

AN UNINTENTIONAL ROOF FALL OCCURRED 9-14-2000 ON THE D-3 MAINS BELT (NO. 6 BELT), NO. 5 ENTRY, 1 BREAK INBY SURVEY STATION NO. 3718. THE FALL WAS APPROX 24' LONG X 18' WIDE X 7' HIGH. THE AREA WAS DEVELOPED 2/99. THE FALL CONTAINED 5' RESIN TENSION BNOLTS, CRIBS & TIMBERS. THE FALL CAVITY WAS RESUPPORTED TO PLAN & THE FALL MATERIAL WAS CLEANED UP.

Source

Authoritative
MSHA Open Government Data
Machine