# FALL OF ROOF OR BACK
> MSHA accident `220002650047` · 09/09/2000 · Wayne Processing Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Rex  Fought
- **Operator:** Wayne Processing Inc
- **Mine:** [4608622](https://api.ai-analytics.org/mine/4608622)
## Narrative

AN UNINTENTIONAL ROOF FALL OCCURRED IN THE E-PANEL 1 BREAK INBY SURVEY STATION 5019 MMU NO. 002-0. THE FALL INVOLVED THE 2-1 XCUTS #2 INTERSECTION & THE #3-2 XCUT. THE FALL WAS APPROX. 90' LON G X 17 1/2' WIDE X 7' HIGH.THE FALL CONTAINED 5' RESIN TENSION BOLTS. THE FALL WILL NOT BE CLEANED UP. ADD. SUPPORT WAS ADDED AROUND THE FALL IN THE FORM OF CRIBS. THE FALL WAS DANGERED OFF.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*