AN UNINTENTIONAL ROOF FALL WAS DISCOVERED 9-12-00 AT 1330 ON E-MAINS NO 3 ENTRY BEGINNING 20' INBY SPAD 4698 FOR 1 BREAK & NO. 4 ENTRY FOR 2 BRREAKS & NO.5 ENTRY FOR 2 BREAKS. THE FALL WAS APP ROX. 550' LONG X 18' WIDE X 7' HIGH. THE FALL CONTAINED 5' RESIN TENSION & 14' CABLE BOLTS. THE FALL WILL NOT BE CLEANED UP AT THIS TIME. THE FALL HAS BEEN DANGERED OFF.