← MSHA accidents

FALL OF ROOF OR BACK

220002660027 · 09/12/2000 · Clinchfield Coal Company

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
Pittston Company
Operator
Clinchfield Coal Company
Mine
4406444

Narrative

A ROOF FALL WAS DISCOVERED ON SOUTHWEST MAINS 00UNIT IN #7 ENTRY APPROX 80FT OUTBY SURVEY STATION761. FALL MEASURED APPROX 80FT L, 18FT W, & 5-6FT HIGH. AREA WAS PREVIOUSLY SUPPORTED WITH 1/3O TO 5FT FULL GROUTED RESIN & 2/3 6FT TORQUE TENSIION REBAR. FALL WILL NOT BE CLEANED UP NO VENTILATION EQUIPMENT OR PERSONS EFFECTED

Source

Authoritative
MSHA Open Government Data
Machine