AN UNINTENTIONAL ROOF FALL WAS DISCOVERED ON 9-27-00 ON E-1 PANEL, NO. 5 ENTRY INTERSECTION 25-6 CROSSCUT AT SURVEY STATION NO. 5130. THE FALL CONTAINED 5 FT RESIN TENSION BOLTS AND WAS DEVELO PED 8-28-2000. THE FALL WAS APPROX. 45 FT LONG X17 FT WIDE X 6-7 FT HIGH. TIMBERS AND CRIBS WERE INSTALLED AT APPROACHES AND THE FALL WAS DANGERED OFF. THE FALL WILL NOT BE CLEANED UP AT THIS