TAILGATE ENTRY FELL IN ADJACENT TO THE LONGWALL FACE AT APPROX 2045 FOOT MAKR FROM THE PANEL STARTLINE. THE FALL OCCURED AT THE JUNCTION OF THE FRONTAL LONGWALL ABUTMENT PRESSURE ZONE & THE TAILGATE ABUTMENT ZONE AT THE I JUNCTION OF THE TAILGATE ADDL STANDING SUPPORT IN THE FORM OF CRIBS HAS BEEN SET IN THE NEXT OUTBY INTERSECTIONSOF THE TAILGATE THE FALL WAS APPROX 3'H, 12'LONG