AN UNINTENTIONAL ROOF FALL OCCURRED ON NO.4 BELT AT SPAD NO. 1054 ON A-MAINS. THE FALL EXTENDED FROM NO. 8 ENTRY TO THE BELT ENTRY (NO. 6) INTERSECTION. THE FALL WAS APPROX 110 FT LONG BY 17 F T WIDE BY 12 FT HIGH. THE FALL CONTAINED 6 FT RESIN BOLTS, 10 FT CABLE BOLTS. THE AREA WAS DEVELOPED 9-20-98. THE BELT ENTRY PORTION WAS CLEANED UP.