← MSHA accidents

FALL OF ROOF OR BACK

220002900132 · 10/05/2000 · Wayne Processing Inc

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
Rex Fought
Operator
Wayne Processing Inc
Mine
4608622

Narrative

AN UNINTENTIONAL ROOF FALL OCCURRED ON NO.4 BELT AT SPAD NO. 1054 ON A-MAINS. THE FALL EXTENDED FROM NO. 8 ENTRY TO THE BELT ENTRY (NO. 6) INTERSECTION. THE FALL WAS APPROX 110 FT LONG BY 17 F T WIDE BY 12 FT HIGH. THE FALL CONTAINED 6 FT RESIN BOLTS, 10 FT CABLE BOLTS. THE AREA WAS DEVELOPED 9-20-98. THE BELT ENTRY PORTION WAS CLEANED UP.

Source

Authoritative
MSHA Open Government Data
Machine
JSON-LD · Markdown