← MSHA accidents

FALL OF ROOF OR BACK

220003180149 · 11/01/2000 · Consolidation Coal Company

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
CONSOL Energy Inc
Operator
Consolidation Coal Company
Mine
4404856

Narrative

AN UNINTENTIONAL ROOF FALL WAS DISCOVERED ON THE1-NORTH MAINS #5 ENTRY AT SPAD #604. FALL MEASURED ABOUT 60' LONG, 20' WIDE, UNKNOWN HEIGHT. THEAREA WAS SUPPORTED WITH 5' RESIN BOLTS. THE FALL WILL NOT BE CLEANED UP. NO INJURIES OR EQUIPMENTCAUGHT AS A RESULT OF THIS FALL.