← MSHA accidents

IGNITION OR EXPLOSION OF GAS OR DUST

220003540031 · 11/17/2000 · Eastern Associated Coal LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
IGNITION OR EXPLOSION OF GAS OR DUST
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
Peabody Energy Corporation
Operator
Eastern Associated Coal LLC
Mine
4601456

Narrative

A FRICTIONAL IGNITION OCCURED AT THE #53 SHIELD ON THE 8RT LONGWALL FACE. THE FLAME EMANIATED AT THE CENT OF THE HEAD END SHEARER DRUM & EXTENDED TO THE TAIL END SHEAER DRUM. THE IGNITION WH ILE THE SHEARER WAS CUTTING TO THE HEADGATE, WHEN THE BELTS STRUCK A SULPHER INCLUSION LOCATED IN THE FACE. THE FLAMES WERE EXTINGUISHED WITH WATER HOSE IN 3 MINUTES

Source

Authoritative
MSHA Open Government Data
Machine