← MSHA accidents

FALL OF ROOF OR BACK

220010020012 · 12/27/2000 · —

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
Mine experience
— years

Operator

Controller (parent)
Operator
Mine
1102997

Narrative

AN UNINTENTIONAL ROOF FALL OCCURRED IN THE 4 WAY INTERSECTION OF ENTRY 2 ON THE 002 MMU @ 1+ 100. THE FALL WAS 50' LONG, 18' WIDE AND7' HIGH (THICK. DID NOT IMPAIR VENTILATION OR IMPEDE TRAVEL . THE AREA WAS DEVELOPED 12-26-00 & SUPPORTED WITH 6' FULLY GROUTED ROOF BOLTS & ALSO WAS CRIBBED OFF WITH SEVERAL CRIBS.

Source

Authoritative
MSHA Open Government Data
Machine