# FALL OF ROOF OR BACK
> MSHA accident `220010040005` · 12/27/2000 · Addington Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Pittston Company
- **Operator:** Addington Inc
- **Mine:** [1517287](https://api.ai-analytics.org/mine/1517287)
## Narrative

AN UNINTENTIONAL ROOF FALL OCCURRED ON THE 002 MMU IN THE NO 8 ENTRY IMMEDIATELY OUTBY THE FACE. THE FALL MEASURED 70'L X 20' X 8' TO 11'THICK. NO INJURIES OR EQUIPMENT DAMAGE OCCURRED AS A RE SULT OF THE FALL. INSTALLED ROOF BOLTS WERE 5' COMBINATION BOLT. THE FALL AREA WAS BARRICADED AND ADDITIONAL SUPPORT (CRIBS) WERE SET AT ENTRANCES. THE FALL WILL NOT BE REHABILITATED.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*