← MSHA accidents

HOISTING

220010040010 · 12/24/2000 · Consolidation Coal Company

Details

Degree of injury
ACCIDENT ONLY
Classification
HOISTING
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
Mine experience
— years

Operator

Controller (parent)
CONSOL Energy Inc
Operator
Consolidation Coal Company
Mine
1100601

Narrative

NASON HOIST KICKED OUT AND AFTER BEING RESET WOULD KICK OUT WHEN STARTED. SYSTEM HAD TO BE REPROGRAMED AND WAS BACK IN SERVICE @ 4 AM 12/25/00. THESE PROBLEMS OCCURRED DUE TO INCREASE IN POWER COMPANY LINES FROM 138,000 UP TO 145,000 VOLTS.