← MSHA accidents
FALL OF ROOF OR BACK
220010180015 · 01/09/2001 · Papaw Coal Company Inc
Details
Degree of injury ACCIDENT ONLY
Classification FALL OF ROOF OR BACK
Accident type Accident type, without injuries
Occupation —
Activity —
Injury source —
Nature of injury —
Body part —
Days lost —
Mine experience — years
Operator
Controller (parent) Mark S Wooten
Operator Papaw Coal Company Inc
Mine 4406984
Narrative ROOF FALL LOCATED AT #5 HEADING FAN ENTRANCE MEASURING ABOUT 25' LONG INBY SPAD #8. FALL ABOUT 5TO 6' HIGH & 18 TO 20' WIDE. APPROXIMATELY 1800 TO 2000' GONE FROM FACE.
Source
Authoritative MSHA Open Government Data
Machine JSON-LD · Markdown
MSHA mine accident data · AI Analytics CC0 1.0