# FALL OF ROOF OR BACK
> MSHA accident `220010220107` · 01/11/2001 · Performance Coal Company
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Massey Energy Company
- **Operator:** Performance Coal Company
- **Mine:** [4608436](https://api.ai-analytics.org/mine/4608436)
## Narrative

AN UNINTENTIONAL ROOF FALL ON NORTH MAIN ENTRY #3 AT SPAD 6569 WAS 90 FT LONG 20 FT WIDE AND 4 FT THICK. THE FALL WAS ABOVE ANCHOR. 4 FT RESIN BELT WAS USED ALONG WITH TEMBERST CRIBS. PASSAGE WAS BLOCKED. VENTILATION WAS NOT AFFECTED, NO EQUIPMENT WAS DAMAGED AND NO INJURY.

---