A ROOF FALL HAS OCCURRED IN THE HEAD GATE ENTRY OF THE C-3 LONGWALL PANEL JUST OUTBY THE LONGWALL FACT AT SURVEY STATION 6948. THE FALL MEASUREDUP TO 86 FT IN LENGTH, 20 FT IN WIDTH, & APPROX 9 FT HIGH. THE FALL MATERIAL CONSISTED OF APPROX3.5 FT OF LIMESTONE & SAND, SHALE 5 FT ABOVE. THE AREA HAD BEEN BOLTED WITH 4' RESIN BOLTS