# FALL OF ROOF OR BACK
> MSHA accident `220010290090` · 01/20/2001 · Independence Coal Company Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Massey Energy Company
- **Operator:** Independence Coal Company Inc
- **Mine:** [4608492](https://api.ai-analytics.org/mine/4608492)
## Narrative

AN UNPLANNED ROOF FALL OCCURRED ON 1-20-01. LOCATION OF THE FALL WAS AT SECTION 003, ENTRY #6, SPAD #2822. DISTANCE FROM THE ACTIVE FACE WAS 200 FEET. THERE WERE NO PERSONAL INJURIES AND NO EQ UIPMENT WAS INVOLVED. SIZE OF FALL UNEASURED 120FT X 19FT X 7FT. ALL ENTRANCES TO THE FULL HAVE BEEN BREAKERED OFF AND THE FALL AREA WILL BE REHABILITATED.

---