← MSHA accidents

FALL OF ROOF OR BACK

220010300019 · 01/13/2001 · Consol Of Kentucky Inc

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
CONSOL Energy Inc
Operator
Consol Of Kentucky Inc
Mine
1518212

Narrative

AN UNINTENTIONAL ROCKFALL OCCURRED ON 1-13-01 IN THE #4 ENTRY AT #87 BREAK. FALL WAS APPROXIMATELY 60'L X 45'W X 6-8'H. NO INJURIES, #3 MOBIL BRIDGE WAS CAUGHT, VENTILATION WAS NOT INTERUPTED. THE AREA HAD BEEN BOLTED WITH 5' FULLY GROUTED RESIN BOLTS. FALL WILL BE CLEANED UP.

Source

Authoritative
MSHA Open Government Data