A ROOF FALL HAS OCCURRED ON THE C-3 LONGWALL FACE AT THE TIME THAT THE EQUIPMENT ON THAT FACE WAS BEING REMOVED. DURING THE RECOVERY OF THE SHIELDS A FALL OCCURRED BETWEEN SHIELD NO'S 92 AND 1 02. THE FALL WAS APPROX 53 FEET LONG X 7 FEET WIDE AND IN EXCESS OF 6 FEET HIGH. THE AREA HAD BEEN BOLTED WITH 4 FEET LONG RESIN GROUTED BOLTS WITH STRAPS.