AN UNINTENTIONAL ROOF FALL WAS DISCOVERED IN THE #6 MAINS IN THE #7 ENTRY AT #82 BREAK. FALL WAS APPROX 25' BY 25' BY 4-6' HIGH. NO INJURIES, NO EQUIPMENT CAUGHT, VENTILATION WAS NOT INTERUPTE D. THE AREA WAS SUPPORTED WITH 4' FULLY GROUTED RESIN BOLTS.