← MSHA accidents

FALL OF ROOF OR BACK

220010510155 · 02/12/2001 · Solar Sources Underground L L C

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
Felson Bowman
Operator
Solar Sources Underground L L C
Mine
1202103

Narrative

AN UNINTENTIONAL ROOF FALL OCCURRED IN 3 SOUTH -2 EAST PANEL, #1 ENTRY AT #42 CROSSCUT. THE ROOF FALL WAS 80'L X 18'W X 6'H. LOCATED IN THE RETURN AIR COURSE AT #42 CROSSCUT IN A THREE WAY INT ERSECTION. THE FALL WAS TIMBERED OFF AND WILL NOT BE CLEANED UP.

Source

Authoritative
MSHA Open Government Data
Machine
JSON-LD · Markdown