← MSHA accidents

FALL OF ROOF OR BACK

220010640042 · 02/25/2001 · —

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
—
Operator
—
Mine
1102997

Narrative

AN UNINTENTIONAL ROFF FALL OCCURRED IN THE 4-WAYINTERSECTION OF THE #7 ENTRY AT 12+20 IN THE 6TH NORTH. THE FALL 60' LONG, 19' WIDE AND 5' THICK. DID NOT AFFECT TRAVEL OR IMPAIR VENTILATION. T HE ROOF WAS SUPPORTED BY 4' FULLY GROUTED ROOF BOLTS INSTALLED BY OUR CURRRENT ROOF CONTROL PLAN. THE INTERSECTION WAS DEVELOPED IN DEC. 2000.

Source

Authoritative
MSHA Open Government Data
Machine