AN UNINTENTIONAL ROOF FALL OCCURRED ON THE D-8 PANEL NO. 2 ENTRY INTERSECTION AT SURVEY STATION NO. 6076. THE FALL IS APPROX 40 FT X 18 FT WIDE X 8-14 FT HIGH. THE FALL CONTAINED 6 FT RESIN A ND 14 FT CABLE BOLTS. THE AREA WAS DEVELOPED 3-21-01. THE FALL HAS BEEN DANGERED OFF AND APPROACHES CRIBBED. THE FALL WILL NOT BE CLEANED UP.