# FALL OF ROOF OR BACK
> MSHA accident `220010990149` · 03/30/2001 · Wayne Processing Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Rex  Fought
- **Operator:** Wayne Processing Inc
- **Mine:** [4608622](https://api.ai-analytics.org/mine/4608622)
## Narrative

A ROOF FALL OCCURRED ON THE E-3 PANEL 002-0, NO. 7 ENTRY INTERSECTION AND CROSSCUTS 90 6 & 8 INTERSECTIONS 1 BREAK INBY SURVEY STATION NO. 6079. THE FALL CONTAINED 6 FT. RESIN AND 14 FT CABLE BOLTS. THE FALL IS APPROX. 70 FT LONG X 18 FT WIDE X 7-15 FT HIGH. THE AREA WAS DEVELOPED 3-28-01. THE FALL HAS BEEN DANGERED OFF, WILL NOT BE CLEANED UP.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*