AN EXTENSION OF THE FALL ON THE 002-0 MMU E-3 PANEL OCCURRED AT 10:00 PM ON 3-30-01. THE FALL CONTINUED THRU THE NO. 8 INTERSECTION CROSSCUT & NO. 9 INTERSECTION 1 BREAK INBY SURVEY STATION 60 79. THIS FALL WAS AN ADDITIONAL 60 FT LONG X 18 FT WIDE X 7-15 FT HIGH. THE AREA WAS CRIBBED AND DANGERED OFF. AREA WAS DEVELOPED 3-28-01 AND CONTAINED 6 FT RESIN & 14 FT CABLE BOLTS.