# FALL OF ROOF OR BACK
> MSHA accident `220011170073` · 04/11/2001 · Anker West Virginia Mining Company Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Anker Group Inc
- **Operator:** Anker West Virginia Mining Company Inc
- **Mine:** [4608622](https://api.ai-analytics.org/mine/4608622)
## Narrative

A ROOF FALL WAS DISCOVERED ON C-MAINS STARTING AT SURVEY STATION NO. 4475 IN NO. 10 ENTRY. IT EXTENDED FOR 180' DOWN NO. 10 ENTRY THROUGH THE X-CUT FOR 80' TO THE EDGE OF NO. 8 ENTRY. THE FALL WAS 23' LONG X 17 1/2' WIDE X 7' HIGH. THE AREA WAS DEVELOPED 4/2000. THE FALL HAS BEEN DANGEREDOFF & TIMBERS SET AT THE APPROACHES. IT WILL NOTBE CLEANED UP AT THIS TIME.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*