# FALL OF ROOF OR BACK
> MSHA accident `220011350019` · 04/30/2001 · Aero Energy Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Rex  Fought
- **Operator:** Aero Energy Inc
- **Mine:** [1502085](https://api.ai-analytics.org/mine/1502085)
## Narrative

THIS MINE HAS EXPERIENCED A NON-INJURY, UNINTENTIONAL ROOF FALL OFF SECTION FOR MMU 014-0 IN #5 NEUTRAL ENTRY AT SS NO. 160 & EXTENDING INBY TO SURVEY SPAD NO. 161 APPROX. 120'. THIS AREA IS O N 14-E PANEL OUTBY THE SECTION. FALL WAS APPROX.120' LONG, 5' TO 6' THICK & 18' TO 20' WIDE. NO PROPERTY DAMAGE. PASSAGE WAS NOT IMPEDED NOR VENTILATION AFFECTED.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*