AN UNINTENTIONAL ROOF FALL OCCURRED ON THE GALATIA NORTH 10, 1070' WEST ENTRY #3 (4W) HEADGATE OFF 5W LONGWALL. THE FALL WAS APPROX 40' LONG BY 10-15' WIDE BY APPROX 6-10' THICK. THE FALL DID NOT AFFECT VENTILATION OR PASSAGE OF MINERS. THEFALL AREA WILL FALL 18E.