# FALL OF ROOF OR BACK
> MSHA accident `220011520027` · 05/17/2001 · Anker West Virginia Mining Company Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Anker Group Inc
- **Operator:** Anker West Virginia Mining Company Inc
- **Mine:** [4608622](https://api.ai-analytics.org/mine/4608622)
## Narrative

A ROOF FALL WAS DISCOVERED ON D-8 PANEL, NO. 4 ENTRY & INTERSECTION, 80' INBY SURVEY STATION 6053. THE FALL WAS APPROX. 70' LONG X 18' WIDE X 12' HIGH. THE FALL CONTAINED 6' & 8' RESIN BOLTS. THE AREA WAS DEVELOPED 4-1-01. THE FALL HAS BEEN DANGERED OFF & WILL NOT BE CLEANED UP.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*