# ELECTRICAL
> MSHA accident `220011970134` · 07/10/2001 · N A Degerstrom Inc
## Details
- **Degree of injury:** PERM TOT OR PERM PRTL DISABLTY
- **Classification:** ELECTRICAL
- **Accident type:** Contact with electrical current
- **Occupation:** Truck driver
- **Activity:** Handling supplies or material
- **Injury source:** CONDCTR,ELCT,CBL,TROL POL
- **Nature of injury:** AMPUTATION OR ENUCLEATION
- **Body part:** LOWER LEG/TIBIA/FIBULA
- **Days lost:** —
- **Mine experience:** 4 years
## Operator
- **Controller:** N A Degerstrom
- **Operator:** N A Degerstrom Inc
- **Mine:** [4502995](https://api.ai-analytics.org/mine/4502995)
## Narrative

A 35-TON MOBILE CRANE CONTACTED HIGH-VOLTAGE POWER TRANSMISSION LINES WHILE MOVING AN EMPTY 5,000 GALLON WATER TANK. A MINER TENDING THE TAG-LINE RECEIVED SERIOUS ELECTRICAL BURNS AS A RESULT OF THE CONTACT.

---