← MSHA accidents

FALL OF ROOF OR BACK

220011970167 · 07/08/2001 · Aero Energy Inc

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
Rex Fought
Operator
Aero Energy Inc
Mine
1502085

Narrative

THE MINE EXPERIENCED A NON-INJURY, UNINTENTIONALROOF FALL OUTBY THE ACTIVE 14 SECTION ON 14-E PANEL IN #6 ENTRY (NEUTRAL). FALL WAS ~200' LONG, 20' WIDE & 4'-6' THICK. LAMINATED SHALE AND SAND STONE. NO DAMAGE TO PROPERTY. AREA WAS INITIALLYSUPPORTED WITH 60"" FULLY GROUTED RODS WITH STRAPS AND CRIBS.

Source

Authoritative
MSHA Open Government Data
Machine
JSON-LD · Markdown