A ROOF FALL OCCURRED ON 004 SECTION IN THE #2 LT XCUT, ON 10 LT FACE. THE MINER HAD MINED APPROX. 20' AND MOVED TO ANOTHER PLACE. BEFORE THE BOLTER GOT TO IT, THE CUT FELL AND RODE INTO THE IN TERSECTION THAT WAS BOLTED WITH 5' RESIN BOLTS. THE FALL WAS APPROX. 18' X 40' X 5 1/2' THICK.