A NON INJURY ROOF FALL WAS FOUND BY THE 3RD SHIFT CREW AS THEY CAME OUT OF THE MINE. A ROOF FALL 40' INBY THE PORTAL ON THE #4 ROADWAY, THE FALL 18' WIDE X 60' LONG X 4' HIGH IS AT SPAD #7. TH E ROOF WAS SUPPORTED BY 4' RESIN PINS AND 7 SETS OF HEINTZMAN WITH 100TON JACKS ON EACH SIDE OF THE 7 SETS.