# FALL OF ROOF OR BACK
> MSHA accident `220012620035` · 09/14/2001 · Independence Coal Company Incorporated
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Massey Energy Company
- **Operator:** Independence Coal Company Incorporated
- **Mine:** [4608513](https://api.ai-analytics.org/mine/4608513)
## Narrative

AN UNPLANNED ROOF FALL OCCURRED 9/14/01 & WAS DISCOVERED APPROX 1:44 AM. FALL IS LOCATED IN THE #2 ENTRY, SPAD 43. VENTILATION IS NOT AFFECTED. FALL MEASURES 45 X 18 X 10. SUPPORTED BY 5' RESI N BOLTS. THE FALL WILL BE DANGERED OFF.

---