AN UNINTENTIONAL ROOF FALL 10' WIDE BY 35' LONG BY 4' THICK FELL ONTO THE RIPPERS OF THE CONTINUOUS MINER STOPPING THE MACHINE FOR APPROX 100 MIN. THE FALL OCCURRED TO CROSSCUT BETWEEN #25 ENT RY SPAD1681 #3SPAD 1678 WHILE MINER WAS TRAMMINGFROM THE #5 AND FINAL LIFT FROM THE #2 BLOCK OF PILLARS BEING MINER AREA TIMBERED OFF.