ROOF FALL OCCURRED IN THE FACE OF THE #2 ENTRY #2 SECTION. FALL MEASURED APPROX 4 FT WIDE 2' RIDER THICK BY 20 FT WIDE BY 30' LONG. THIS AREA WAS MINED 11-26-01. BOLTED WITH 4' RESIN BOLTS. NO EMPLOYEES OR EQUIPMENT WAS INVOLVED. NO AIRWAY OR TRAVELWAY WAS EFFECTED. THIS AREA IS CRIBBED AND DANGERED OFF.