FALL OF ROOF OR BACK

220020070065 · 12/27/2001 · Steyer Fuel Inc

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
David M Maynard
Operator
Steyer Fuel Inc
Mine
1800724

Narrative

EMPLOYEE FOUND ROOF FALL ON 7 NORTH WEST PANEL IN #2 ENTRY, SPAD 5031, 9 BLOCKS OUT BY FACE. THE FALL WENT FROM SPAD 5031 TO IN BY INTERSECTION AND FROM SAME SPAD THRU X-CUT TOWARDS #3 ENTRY. TIMBERED OFF ALL ENTRYS TO FALL. FALL IS 40' BY 18' WIDE BY 5 1/2' HIGH AND 30' LONG BY 18' WIDE BY 5 1/2' HIGH THRU X-CUT.