# FALL OF ROOF OR BACK
> MSHA accident `220020220052` · 01/13/2002 · Freeman United Coal Mining Company
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** General Dynamics Corp
- **Operator:** Freeman United Coal Mining Company
- **Mine:** [1102632](https://api.ai-analytics.org/mine/1102632)
## Narrative

A ROOF FALL OCCURRED INT HE 12 TH EAST, #3 ENTRY, AT 4210' STATION. THE FALL WAS 25' WIDE 25' LONG, AND 8' HIGH. IT DID NOT AFFECT VENTIALTION TRAVEL DAMAGE EQUIPMENT OR CAUSE ANY INJURY. THE AREA WAS BOLTED WITH 8' POINT ANCHOR BOLTS.

---